Sanipro UP Non Return Valve

£19.99

Sanipro UP Non Return Valve

Part Fits:

Saniflo Sanitop Sanipro-XR Sanislim Saniplus Sanipack Saniwall Saniaccess Saniflo UP, Sanipro UP, Saniplus UP Sanipack UP, Sanislim UP, Saniwall Pro UP Sanitop UP.

Coude blanc complet avec clapet anti retour

Macerator non return valve, prevents waste water flowing back in to the macerator pump.

Availability: In stock (can be backordered)

Sanipro UP Macerator Non Return Valve

Part Fits:

Sanitop Sanitop UP, Sanipro-XR Sanislim, Saniplus, Sanipack, Saniwall, Saniaccess, Sanitop UP, Sanipro UP, Saniplus UP Sanipack UP, Sanislim UP, Saniwall Pro UP, Sanitop UP pumps.

Is your Sanipro UP activating intermittently? If the answer is yes you most probably need a non return which is also called a discharge elbow which is used for waste disposal .

The non return which is found on the top of the Macerator pumps and connects to the flexible waste pipe stops waste water flowing back in to the Macerator pump and setting it off.

If your waste outlet pipe runs vertical up the wall then out to the soil stack and your Sanipro UP or any other macerator pumps is activating intermittently then try replacing the non return.

If you live in a hard water area and have never Descaled your Sanipro UP then the chances are your non return has thick limescale on the rubber return valve and is preventing it from closing and sealing properly.

Activation times can vary, if activates quickly chances are the rubber valve is completely missing, if it takes a while then you have a slow leaky valve.

Sometimes if the rubber on the Sanipro UP macerator non return doesn’t have limescale damage and is not sealing could be the rubber has been damaged either by a foreign object or the rubber has been damaged by chemicals and the rubber valve has enlarged or is distorted.

If you have to change the valve make sure you use Descaler afterwards to clean out the machine at regular intervals 2-3 times per year.

Other reasons for intermittent starting are faulty Membranes or faulty microswitches.

What is a Sanipro UP Non Return?

Sanipro UP is a brand of macerating toilet pumps that are commonly used in areas where traditional plumbing is not possible or practical. One of the key components of a Sanipro UP system is the non return, which is a crucial part of the system’s functionality.

What Does a Sanipro UP Non Return Do?

A Sanipro UP non return is designed to prevent waste from flowing back into the macerator pump unit. It is a one-way valve that ensures that once waste enters the pump, it cannot return back up the pipe. This is important for the proper functioning of the Sanipro UP system and prevents the possibility of sewage backup.

How Does a Sanipro UP Non Return Work?

The non return is installed on the discharge pipe of the Sanipro UP pump. It is designed with a rubber diaphragm that allows waste to flow out of the unit, but not back in. When waste flows through the valve, it pushes the diaphragm up, allowing the waste to pass through. Once the waste has passed, the diaphragm falls back down, creating a seal that prevents any backflow.

Why is a Sanipro UP Non Return Important?

Without a non return, wastewater could flow back into the pump unit, causing damage and creating a health hazard. It could also lead to sewage backup, which is both unpleasant and potentially dangerous. The non return ensures that wastewater flows in only one direction, preventing these problems from occurring.

Conclusion

In summary, a Sanipro UP non return is an essential component of the Sanipro UP macerating toilet system. It prevents wastewater from flowing back into the pump unit, ensuring the proper functioning of the system and preventing sewage backup. By understanding how it works and its importance, you can ensure that your Sanipro UP system operates smoothly and efficiently.

Why is my Sanipro UP not turning off?

Sanipro UP is a popular brand of macerating toilet pumps that are designed to efficiently pump waste water from toilets, sinks and other plumbing fixtures. If your Sanipro UP system is not turning off, there could be several reasons for it.

1. Faulty Float Switch

One of the most common reasons for a Sanipro UP not turning off is a faulty float switch. The float switch is responsible for controlling the water level in the grinder unit. If the switch is not working correctly, it may not be able to shut off the unit when the water level reaches a certain point. This can cause Sanipro UP pumps to continue running even when it’s not needed, leading to increased wear and tear on the system.

2. Clogged Pump

Another reason for a Sanipro UP pumps not turning off could be a clogged pump internally. If the pump is blocked with debris or waste, it may not be able to turn off once the water level drops. This can cause the unit to continue running, even when it’s not needed, leading to increased energy consumption and potential damage to the macerator pumps.

3. Electrical Issues

If your Sanipro UP is not turning off, it could be due to electrical issues. This could include a faulty circuit board, damaged wiring, or a malfunctioning motor or damaged microswitch. These issues can prevent the unit from shutting off when it’s supposed to, leading to increased energy consumption and potential damage to the system.

4. Water Pressure Issues

Water pressure issues can also cause some Sanipro UP pumps not turn off. If the water pressure in your plumbing system is too high, it can cause the Sanipro UP to leak water and continue running even when it’s not needed. This can lead to increased wear and tear on the system and potential damage to the unit.

5. Installation Issues

Finally, if your Sanipro UP is not turning off, it could be due to installation issues. If the unit was not installed correctly, it may not be able to function properly, leading to problems like pumps not turning off. In this case, it’s important to have a professional plumber inspect the system and make any necessary repairs or adjustments.

In conclusion, if your Sanipro UP is not turning off, it could be due to a variety of issues, including a faulty float switch, clogged pump, electrical issues, water pressure issues, or installation issues. It’s important to address these issues as soon as possible to prevent further damage to the system and ensure that it’s functioning properly.

Do Sanipro UP pumps Have a Non-Return Valve? A Comprehensive Guide
If you’re considering installing a Sanipro UP system in your home or property, you might be wondering about its safety features and whether it includes a non-return valve. In this article, we will discuss the importance of a non-return valve, its role in a Sanipro UP system and how to maintain it. Let’s dive in!

What is a Non-Return Valve?

A non-return valve, also known as a check valve or one-way valve, is a vital component in many plumbing systems. Its primary purpose is to allow fluid to flow in one direction while preventing it from flowing back in the opposite direction. This helps protect your plumbing system and prevents potential damage or contamination from wastewater.

Do Sanipro UP Systems Have a Non-Return Valve?

Yes, Sanipro UP systems come equipped with a non-return valve as a standard feature. This valve is built into the unit to ensure that wastewater and sewage can only flow away from your property and towards the main drainage system, preventing any backflow or cross-contamination.

Why is a Non-Return Valve Important in a Sanipro UP pumps?

The non-return valve is an essential part of the Sanipro UP system for several reasons:

  • Protection from backflow: The valve stops wastewater from flowing back into your property, which can cause unpleasant odours, hygiene issues and damage to your fixtures and appliances.
  • Maintaining system performance: By preventing backflow, the non-return valve helps maintain the efficiency of your Sanipro UP system, ensuring that waste is pumped out as required.
  • Compliance with regulations: A non-return valve is necessary to meet plumbing regulations and standards, ensuring your Sanipro UP system is safe and legal to install.

How to Maintain the Non-Return Valve in Your Sanipro UP System
Although Sanipro UP systems are designed for easy installation and minimal maintenance, it’s essential to keep the non-return valve in good working order. Here are a few tips for maintaining the valve:

  1. Regularly inspect the valve for any visible damage, wear, or debris that might obstruct its proper function.
  2. Clean the valve as needed to ensure it remains clear and free from blockages.
  3. If you experience any issues with the non-return valve or other parts of your Sanipro UP pumps, contact a qualified professional to assess the situation and perform any necessary repairs.

Choose Sanipro UP for Your Macerator System Needs
Now that you know Sanipro UP systems include a non-return valve, you can feel confident in their performance and safety features. Sanipro UP offers a range of high-quality Sanipro UP systems to suit various needs, including full bathroom installations, cloakrooms and utility rooms.

Buy a Sanipro UP non return valve Replacement